mptgen#
- Materials.mptgen(stloc='', num='', tstrt='', tinc='', **kwargs)#
Adds temperatures to the temperature table by generation.
Mechanical APDL Command: MPTGEN
- Parameters:
- stloc
str Starting location in table for generating temperatures. Defaults to last location filled + 1.
- num
str Number of temperatures to be generated (1-100).
- tstrt
str Temperature assigned to
STLOClocation.- tinc
str Increment previous temperature by
TINCand assign to next location until allNUMlocations are filled.
- stloc
Notes
Adds temperatures to the temperature table by generation. May be used in combination (or in place of) the mptemp command.
This command is also valid in SOLUTION.