ansys.mapdl.core.Mapdl.magopt#
- Mapdl.magopt(value='', **kwargs)#
Specifies options for a 3D magnetostatic field analysis.
Mechanical APDL Command: MAGOPT
- Parameters:
- value
intorstr Option key:
0- Calculate a complete H field solution in the entire domain using a single (reduced) potential.Warning
When used in problems with both current sources and iron regions, errors may result due to numerical cancellation.
1- Calculate and store a preliminary H field in “iron” regions (μ:sub:r ≠ 1). Requires flux-parallel boundary conditions to be specified on exterior iron boundaries. Used in conjunction with subsequent solutions withVALUE= 2 followed byVALUE= 3. Applicable to multiply- connected iron domain problems.2- Calculate and store a preliminary H field in “air” regions (μ:sub:r = 1). The air-iron interface is appropriately treated internally by the program. Used in conjunction with a subsequent solution withVALUE= 3. Applicable to singly-connected iron domain problems (with subsequent solution withVALUE= 3) or to multiply-connected iron domain problems (when preceded by a solution withVALUE= 1 and followed by a solution withVALUE= 3).3- Use the previously stored H field solution(s) and calculate the complete H field.
- value
Notes
Specifies the solution sequence options for a 3D magnetostatic field analysis using a scalar potential (MAG). The solution sequence is determined by the nature of the problem.
You cannot use constraint equations with
Value= 1.This command is also valid in PREP7.
Distributed-Memory Parallel (DMP) Restriction magopt,3 is not supported in a DMP solution when the following contact elements are present in the model:
CONTA174,CONTA175, orCONTA177.