rose#

SpectrumOptions.rose(signif='', label='', td='', forcetype='', **kwargs)#

Specifies the Rosenblueth mode combination method.

Mechanical APDL Command: ROSE

Parameters:
signifstr

Combine only those modes whose significance level exceeds the SIGNIF threshold. For single point, multipoint, or DDAM response ( spopt, SPRS, MPRS, or DDAM), the significance level of a mode is defined as the mode coefficient divided by the maximum mode coefficient of all modes. Any mode whose significance level is less than SIGNIF is considered insignificant and does not contribute to the mode combinations. The higher the SIGNIF threshold, the fewer the number of modes combined. SIGNIF defaults to 0.001. If SIGNIF is specified as 0.0, it is taken as 0.0. (This mode combination method is not valid for spopt,PSD.)

labelstr

Label identifying the combined mode solution output.

  • DISP - Displacement solution (default). Displacements, stresses, forces, etc., are available.

  • VELO - Velocity solution. Velocities, “stress velocities,” “force velocities,” etc., are available.

  • ACEL - Acceleration solution. Accelerations, “stress accelerations,” “force accelerations,” etc. are available.

tdstr

Time duration for earthquake or shock spectrum. TD defaults to 10.

forcetypestr

Label identifying the forces to be combined:

  • STATIC - Combine the modal static forces (default).

  • TOTAL - Combine the modal static plus inertial forces.

Notes

For more information on spectrum analysis combination methods, see Combination of Modes

This command is also valid in PREP7.