Mapdl.plopts(label='', key='', **kwargs)#

Controls graphics options on subsequent displays.

APDL Command: /PLOPTS

Parameters:
label

Apply display items as selected from the following labels:

INFO

Controls the display of the legend (ON or OFF) and allows the choice of preset or Multi-legend placement. Control is provided by the KEY values. (Defaults to KEY=3 when the GUI is on. Defaults to KEY= 2 otherwise.)

LEG1

Header portion of legend column (defaults to ON).

LEG2

View portion of legend column (defaults to ON (except off with contour displays)).

LEG3

View the contour section of the legend column (defaults to ON).

FRAME

Frame border lines around windows (defaults to ON).

TITLE

Title (bottom left text) (defaults to ON).

MINM

Min-Max symbols on contour displays (defaults to ON).

LOGO

ANSYS logo (defaults to OFF (displayed as text at top of legend column)). If KEY = ON, the text is removed from legend column but the logo symbol is displayed in whichever active window is either in the uppermost right corner and on top, or if there is no window in that location, then in the window to the furthest right of the screen. Version information remains in the legend column.

WINS

Controls whether graphics windows automatically stretch or shrink to adjust to screen size as the legend column is turned off or on [/PLOPTS,INFO] (defaults to ON). If WINS is on and the legend column is changed from off to on, all windows are shrunk regardless of what their correct size is.

WP

Working plane (defaults to OFF). The working plane is drawn as part of the display (not just an overlaid image as in WPSTYL). This option is best used in combination with a hidden-line technique [/TYPE].

DATE

Controls the display of the date and time in your legend. Subsequent KEY values control the display as follows:

FILE

Controls the display of the ANSYS jobname in your legend. Subsequent KEY values control the display as follows:

key

Switch:

OFF or 0

Do not apply this display item. For Label = DATE, no time or date are displayed.

ON or 1

Apply this display item. For Label = DATE, show only the date.

AUTO or 2

For Label = INFO, initiate Auto-legend mode. If the display has contours, the legend is ON; if the display has no contours, the legend is OFF. For Label = DATE, display both the date and time.

3

For Label = INFO , switch to Multi-legend mode. See the /UDOC command for the available legend configurations.

Notes

Use /PLOPTS,STAT to display settings. Use /PLOPTS,DEFA to reset all specifications back to their defaults.

When you perform multiple results displays, contours on the legend column may be truncated. To avoid this, specify /PLOPTS,LEG1,0.

The Multi-legend mode provides a number of legend data item priority and placement options. These options are accessed via the GUI at Utility Menu> PlotCtrls> Window Controls> Window Options. The /UDOC command provides command line options for this capability.

This command is valid in any processor.

This command is not available for Academic Research or Teaching level products