data#
- Mapdl.data(ir='', lstrt='', lstop='', linc='', name='', kcplx='', **kwargs)#
Reads data records from a file into a variable.
APDL Command: DATA
- Parameters:
- ir
Arbitrary reference number assigned to the resulting variable (2 to NV [NUMVAR]). If this number is the same as for a previously defined variable, the previously defined variable will be overwritten with this result.
- lstrt
Start at location LSTRT (defaults to 1).
- lstop
Stop at location LSTOP (defaults to LSTRT). Maximum location available is determined from data previously stored.
- linc
Fill every LINC location between LSTRT and LSTOP (defaults to 1).
- name
Eight character name for identifying the variable on the printout and displays. Embedded blanks are compressed upon output.
- kcplx
Complex number key:
0 - Data stored as the real part of the complex number.
1 - Data stored as the imaginary part of the complex number.
Notes
This command must be followed by a format statement (on the next line) and the subsequent data records, and all must be on the same file (that may then be read with the /INPUT command). The format specifies the number of fields to be read per record, the field width, and the placement of the decimal point (if one is not included in the data value). The read operation follows the available FORTRAN FORMAT conventions of the system. See the system FORTRAN manual for details. Any standard FORTRAN real format (such as (4F6.0), (F2.0,2X,F12.0), etc.) may be used. Integer (I), character (A), and list-directed (*) descriptors may not be used. The parentheses must be included in the format. Up to 80 columns per record may be read. Locations may be filled within a range. Previous data in the range will be overwritten.